After the boiler is stopped, it must be maintained to prevent corrosion in the pot.
Short-term maintenance. The wet maintenance method can be adopted; When the stove is stopped, fill the stove and drain the air.
2.短期保养。可采用湿保养法;即停炉后,将炉水加满,将空气全部排出。
Long-term maintenance. Can use dry maintenance method, namely after the furnace put off the boiler water, open the bottom hand hole, dry of water in the pot, and through the lower hand hole, desiccant, and should be replaced periodically, began to check replacement - times a month, but once every three months later. However, it should be noted that all desiccant will be removed before the boiler is opened.
3.长期保养。可采用干保养法,即停炉后将炉水放掉,打开下部手孔,吹干锅内积水,并通过下部手孔处,投入干燥剂,且应定期更换,开始可每月检查更换—次,以后可三个月一次。但应注意,在锅炉启用前,务必取出全部干燥剂。
The inspection, testing and operation of boiler equipment shall be made in accordance with the specific regulations and the site shall be loaded in the form of ICONS.
锅炉设备的检查、试验及定期操作等项目周期,作出具体的规定,并以图标形式载入现场。
运行人员根据检查的情况及时填写记录。
The operator fill in the record according to the inspection.